In this case, the actual temperature is recorded together
with the fastening sequence.
The system is equipped
with a specific mechanical device that includes a thermal
chamber for temperatures of up to 150°C. During the
measurement sequences, the tension/thread-torque
transducer, specially designed for these
temperatures, is located in the thermal chamber.
The
sensor can easily be taken out of the chamber and placed on
the additional fixture for
standard use for measurements at
room temperature.
Of course, all the
analysis possibilities of the
standard SCHATZ®-ANALYSE System are also available in this
configuration:
- total, head and thread µ friction coefficients,
- measurement range from
M 5 to M 20
/ 1/4 to 3/4 in
5 - 1000 Nm
/ 3.6 - 740ft.lb.,
10 - 300 kN,
/ 2200 - 67500 pound-force
- rotation speeds of up to 240
rpm.
Standard measurement
channels such as total torque,
thread torque,
tension, rotation angle and temperature can be
expanded with other
measurement channels e.g. to measure
elongation of fasteners. Due to
its modular structure the system
can be equipped with up to 30 measurement channels or
modules to record all types of analogue or incremental
signals.
A
very high sampling rates enables
the system to record fast
processes. The automatic transducer
recognition procedure prevents errors due to incorrect
sensor selection. Active transducers
(e.g. +/- 5V) or passive transducers
(strain gage) can be connected to
provide many types of analyses,
such as screw elongation, temperature, etc.
Test procedures can be programmed easily with help of a
programming wizard. Numerical and graphical results can be
evaluated and customized using the powerful
testXpert® software.